Schedule
Part A: ICP Parameters Maintained by Distributors
| ICP Parameter |
Rules governing values assigned |
| ICP Identifier |
The unique 15-character identifier assigned to the ICP by the distributor. |
| ICP creation date |
The date that the distributor deems the ICP to be created, which must be not later than the date that the gas service pipe to the ICP's consumer installation is first livened. It is the earliest date for any event relating to the ICP in the registry. |
| responsible distributor |
The code of the responsible distributor and creator of the ICP. Distributor codes are determined and published by the industry body from time to time. |
| Network Pressure |
The value of the nominal operating pressure, expressed numerically in kilopascals, of the distribution system or transmission system to which the ICP's consumer installation is connected. |
| ICP Altitude |
The altitude, expressed in metres above mean sea level, of the meter measuring gas consumption for the ICP's consumer installation, and for use in any required (non-dynamic) correction of the metered gas volume to standard volume. |
| Gas gate |
The code of the gas gate from which the distributor deems gas is delivered to the ICP's consumer installation. Gas gate codes are determined and published by the industry body from time to time. |
| ICP Type |
The code representing the ICP type. ICP types and ICP type codes are determined and published by the industry body from time to time. |
| ICP Status |
The code representing the ICP status. ICP status is maintained by the responsible distributor under rule 59. At ICP creation and ICP readying, the value is assigned by the registry under rule 53.3. |
| Connection status |
The code representing the connection status. Connection status is maintained by the responsible distributor under rule 60 and in accordance with the requirements published by the industry body under rule 60.2. |
| Load Shedding Category |
The code representing the load shedding category that identifies the position of the ICP's consumer installation in the hierarchy for emergency shedding of gas load. Load shedding categories and codes are determined and published by the industry body from time to time. |
| Maximum Hourly Quantity (MHQ) |
The maximum quantity of gas, in cubic metres, that the gas-consuming equipment at the consumer installation is capable of drawing per hour. The value is distinct from the capacity of the gas service pipe or metering equipment serving the consumer installation. Mandatory only where MHQ is used to determine the distributor's network charges. May be conveyed by means of a "disclosure on application" code in accordance with rule 50. |
| Expected retailer |
The code of the retailer that the distributor expects to be the first responsible retailer for the ICP. |
| Network Price Category |
The code of the network price category to which the ICP belongs, as determined and published by the distributor. The charges associated with the code may be conveyed by means of a "disclosure on application" code in accordance with rule 50. |
| Loss factor Code |
The code that identifies the loss factor applicable to the ICP's consumer installation. |
| Network Price Details |
A free-text parameter to allow the distributor to provide other information relevant to the network pricing of the ICP's consumer installation. |
| Physical Address |
The physical address assigned by the distributor to the ICP's consumer installation, so that the ICP can be unambiguously identified with the consumer installation, in the registry. |
With the exception of the ICP identifier and ICP creation date parameters, each of the parameters in Part A of the Schedule has an associated effective date, being the date from which the current value of the ICP parameter became applicable.
Part B: ICP Parameters Maintained by Retailers
| ICP Parameter |
Rules governing values assigned |
| Responsible retailer |
The code of the retailer with current responsibility for the ICP. Retailer codes are determined and published by the industry body from time to time. |
| ICP status |
The code representing the ICP status. ICP status is maintained by the responsible retailer under in rule 59. |
| Connection status |
The code representing the connection status. connection status is maintained by the responsible retailer in accordance with the requirements published by the industry body under rule 60.2. |
| Allocation Group |
The code represents the allocation group to which the ICP belongs, as published by the industry body from time to time. |
| Profile |
The code that identifies the profile assigned to the ICP. Profile codes are determined and published by the industry body from time to time. |
| responsible meter owner |
The code, of the responsible meter owner. responsible meter owner is assigned according to the authority of a service agreement between the responsible retailer and the meter owner providing the meter measuring consumption for the ICP. meter owner codes are determined and published by the industry body from time to time. |
Each of the parameters in Part B of the Schedule has an associated effective date, being the date from which the current value of the ICP parameter became applicable.
Part C: ICP Parameters Maintained by Meter Owners
| ICP Parameter |
Rules governing values assigned |
| Meter Identifier |
The serial number or other unique identifier of the meter that measures volume consumption for the ICP's consumer installation, as assigned by the meter owner. However, if the consumption information is being measured by difference, the meter identifier value must be "DIFFERENCE". |
| Meter Location Code |
The code, as defined in a published schedule of meter location codes by the meter owner, that advises the location of the meter used to record consumption at the consumer installation. |
| Standard meter |
A 'Y'es or 'N'o value to indicate the use or not of a standard meter (being one that is not a prepay meter ) for measurement of consumption volume for the ICP's consumer installation. |
| Prepay meter |
A 'Y'es or 'N'o value to indicate the use or not of a prepay meter for measurement of consumption volume for the ICP's consumer installation. |
| Logger Owner |
The code of the owner of any datalogger included in the metering equipment measuring consumption volume for the ICP's consumer installation metering - whether or not the datalogger is in use at the time. Logger owner codes are determined and published by the industry body from time to time. |
| Corrector Owner |
The code of the owner of any corrector included in the metering equipment measuring consumption volume for the ICP's consumer installation metering - whether or not the corrector is in use at the time. Corrector owner codes are determined and published by the industry body from time to time. |
| Telemetry Owner |
The code of the owner of any telemetry included in the metering equipment measuring consumption volume for the ICP's consumer installation metering - whether or not the telemetry is in use at the time. Telemetry owner codes are determined and published by the industry body from time to time. |
| Metering Price Category |
The code of the metering price category that identifies the charges applicable to the full set of metering equipment currently used to measure and convey the consumption volume information for the ICP's consumer installation. The codes are as defined and made available by the meter owner. May be conveyed by means of a 'disclosure on application' code in accordance with Rule 50. |
In the case of the 'Y'es and 'N'o values for the 'standard meter' and 'prepay meter' parameters, there may not be more than one 'Y' value between the two parameters, but there may be two 'N' values to signify that the consumer installation is unmetered.
Each of the parameters in Part C of the Schedule has an associated effective date, being the date from which the current value of the ICP parameter became applicable.
Back to Top